Reinforcement Library |
library of reinforcement for different design code can be selected from drop down menu. |
Preferred Bar Size |
program generate the reinforcement layout for preferred bar size. If the requirements are not satisfied, then program search for reinforcement from bar size range. |
Bar Size Range From |
minimum acceptable bar size when preferred bar is not suitable. |
Bar Size Range To |
maximum acceptable bar size when preferred bar is not suitable. |
Concrete Cover |
maximum distance from the face of the bar to surface |
Spacing Min |
minimum distance from the face of one bar to face of other |
Spacing Max |
maximum distance from the face of one bar to face of other |
Spacing Step (for shear) |
increment increase from minimum spacing to accomplish the shear reinforcement layout |
Number of layers for longitudinal rebars |
program uses this number of possible different types of reinforcement layout for designing longitudinal reinforcement |
Number of different types (for shear web) |
program uses this number of possible different types of reinforcement layout for designing shear web reinforcement. |
Maximum number of legs (for shear web) |
maximum number of legs for shear web reinforcement design which can be used. The minimum number of legs is 2 |
Asmin |
Minimum reinforcement area which is used by program for designing reinforcement layout |
Asmax |
Maximum reinforcement area which is used by program for designing reinforcement layout |