Transverse Reinforcement

The transverse reinforcement sizes are based on the tie size used in the final design bar pattern for that story. For ACI the optimization process will segment the column (when required) into one or two segments. One segment is used for all BS8110 / CP65 designs. Then the transverse bar spacing is selected to minimize the transverse reinforcement while still satisfying the capacity requirements and all code and user-prescribed criteria.

Note: All Column design warnings are given for the controlling load combination case and not just the first design warning found.