RAM Structural System Help

Criteria - Beam Design - Reinforcement (BS8110 Design Code)

  • Minimum Clear Bar Cover - Set the cover to the top, bottom, and sides of the beams.
  • Minimum Gap Between Main Bar Layers - Defines the clear bar spacing between the upper or lower main bar layers.
  • Bar Sizes to Consider for Design - Sets the minimum and maximum allowable bar sizes to be used for flexural and shear reinforcement.
  • Shear Reinforcement - Sets the minimum shear reinforcement spacing and number of legs to be used.