RAM Structural System Help

Flange Bracing

Selecting the Assign-Column-Flange Bracing command causes the Assign Column Bracing dialog box to be displayed. From this dialog the engineer can override, on a member by member basis, the global column bracing criteria specified in the Criteria-Flange Bracing dialog. The engineer should specify whether the TOP of the column is braced or unbraced (or should consider the global criteria) in each axis. This command acts with respect to the top of the column element. Note that if a column is broken up by an intermediate story such that separate column finite elements comprise the physical column, then the top of the selected column element will be assigned the specified criteria. When assigning these criteria the user must be careful to select the correct column.

After the appropriate values are specified the engineer can assign the criteria to a single member (click on Single), to multiple members (click on Fence) or to all members (click on All). Be careful of using the ALL and FENCE options for the reason described above. If Single is clicked the dialog will close and a target cursor will be made available. Click on each column to apply the criteria to. If Fence is clicked the dialog will close and a fence cursor will be made available. Click and drag a rectangle around all the sections to apply the criteria to. Note that the criteria are only assigned to steel columns. To return to the dialog to select a different effective length criteria click on the right mouse button.

To view which member axes are using the global criteria and which have been overridden select the appropriate option from the View-Members Dialog.