Response Spectra Analysis
Structural Response Factors (Sa/g): Section 6.4.5
- For rocky, or hard soil sites
- For medium soil sites
- For soft soil sites
Base Shear Modification: Section 7.8.2
This section states that base shear calculated per response spectra case (or time history) should be modified per base shear calculated from the equivalent seismic load case (i.e., ).
The same modification should also be applied to member forces, displacements etc. This is not directly enforced by the program. However, the program provides scale factors in the response spectra load case dialog in which they can be used for scaling results.
Modes to be considered: Section 7.8.4.2
It is the engineer's responsibility to confirm that 90% mass participation is included in response spectra analysis (i.e., Eigenvalue analysis). There is no missing mass correction feature provided by the program if the subspace iteration method is selected for Eigenvalue analysis. On the other hand, the Ritz vector solution includes missing mass correction directly (i.e. static load correction), therefore use of the Ritz vector solution is recommended for this purpose.
Modal Combination: Section 7.8.4.4
Both CQC and SRSS methods are implemented for modal combination of results.
Torsion (or Accidental Torsion): Section 7.9
edi = 1.0esi ± 0.05bi |
= | ||
= | ||
= |
Implementation Details
- Values for is valid for 5% damping. If other value of damping is used, the above values must be modified per Table 3 (for intermediate values of damping, linear interpolation is applied). For damping values larger than 30%, the code does not provide any information. In this case, a constant value of 0.50 is assumed if damping > 30% defined.
- The code does not mention how the spectral values must be calculated if T > 4.0 seconds. In this case, the following is assumed for T>4:
- Response spectra analysis for vertical direction is not implemented in the program.
- Orthogonal response spectra cases are not supported in the program.