Web Plate Design Thickness |
The thickness of the web plate required to resist all the applied loads. |
Web PL Thk Req’d w/Fillet Weld |
The required thickness of the web plate to allow the web plate to be fillet welded to the column flanges. This is a detailing requirement and is specified separately from the thickness required to resist the applied loads. |
Stiffener Dimension |
The Length (L), width (W) and thickness (T) of the stiffeners. Refer to the assumptions and limitations section for the meaning of Side A and Side B. Top refers to the stiffeners required at the elevation of the upper flange of the framing beam/s. Bot refers to the stiffeners required at the elevation of the bottom flange of the framing beam/s. |