RAM Structural System Help

Final Design

SettingDescription
Web Plate Design Thickness The thickness of the web plate required to resist all the applied loads.
Web PL Thk Req’d w/Fillet Weld The required thickness of the web plate to allow the web plate to be fillet welded to the column flanges. This is a detailing requirement and is specified separately from the thickness required to resist the applied loads.
Stiffener Dimension The Length (L), width (W) and thickness (T) of the stiffeners. Refer to the assumptions and limitations section for the meaning of Side A and Side B. Top refers to the stiffeners required at the elevation of the upper flange of the framing beam/s. Bot refers to the stiffeners required at the elevation of the bottom flange of the framing beam/s.