C-Beam Tables - Cellular
A table of SteelFab, Inc. cellular C-Beam™, called RAMSMI.CEL, is provided with the program. Although you can create and edit tables manually, it is not recommended that you modify the RAMSMI.CEL table unless directed by the manufacturer, SteelFab, Inc.. Use spaces, not tabs, between data items. The file name must have the extension .CEL.
The file has the following format:
The first line contains an E or S, indicating English or SI units.
The C-Beam sections are then listed in the following format:
Label TopSize BotSize Dostandard flag
where:
- Label
- the designation for the cellular C-Beam (e.g., LB18x14).
- TopSize
- the label of the wide-flange section used for the top (e.g.,W12 X14).
- BotSize
- the label of the wide-flange section used for the bottom (e.g., W12X16).
- Dostandard
- the standard (ideal) hole diameter Do to be considered.
- flag
-
a single character used to indicate whether the member is to be considered for composite or noncomposite design:
Each label must be unique (the same label can't appear twice in the table) and it is limited to a maximum of 15 characters.
The sections must be listed in order of cost, least expensive first (generally the lightest). RAM Steel Beam Design selects the first member in the table that satisfies all design requirements and constraints.
The following is a sample listing from the RAMSMI.CEL file:
E LB12x10 W8x10 W8x10 7.500 + LB15x12 W10x12 W10x12 10.000 + LB12x13 W8x13 W8x13 7.500 + LB15x12/15 W10x12 W10x15 10.000 * LB18x14 W12x14 W12x14 12.000 + LB15x12/17 W10x12 W10x17 10.000 * LB15x15 W10x15 W10x15 10.000 + LB12x15 W8x15 W8x15 7.500 + LB18x14/16 W12x14 W12x16 12.000 * LB15x12/19 W10x12 W10x19 10.000 * …