Section Cuts - Change
The Label or location of any Section Cut, whether manually generated or automatically generated, may be changed at any time. Selecting Change Section Cut dialog.
opens theChanging the location of a Section Cut will cause the results for the corresponding Wall Panel Group to be cleared. All Bar Patterns in the Wall Panel Group belonging to Wall Panels that are not frozen will be cleared. Any Bar Patterns belonging to frozen Wall Panels, or any Manual Reinforcement assignments in the Wall Panel Group, will not be cleared.
Setting | Description |
---|---|
Label | The Section Cut Label may be changed by typing in the desired text. Note that labels are automatically generated with the form SC + next index number. |
Offset Distance | the distance from the reference edge. The reference edge is listed on the line below the Offset Distance field. Change this value to change the position of the Section Cut. |
Include Beam beneath Wall (if any) | Set this option to consider the forces in beams crossed by any section cut. |
Include Columns at wall ends (if any) | Set this option to consider the forces in columns crossed by any section cut. |
Clicking OK will keep these changes. Clicking Cancel discards the changes.