RAM Structural System Help

Section Cuts - Change

The Label or location of any Section Cut, whether manually generated or automatically generated, may be changed at any time. Selecting Assign > Section Cuts > Change opens the Change Section Cut dialog.

Changing the location of a Section Cut will cause the results for the corresponding Wall Panel Group to be cleared. All Bar Patterns in the Wall Panel Group belonging to Wall Panels that are not frozen will be cleared. Any Bar Patterns belonging to frozen Wall Panels, or any Manual Reinforcement assignments in the Wall Panel Group, will not be cleared.

SettingDescription
Label The Section Cut Label may be changed by typing in the desired text. Note that labels are automatically generated with the form SC + next index number.
Offset Distance the distance from the reference edge. The reference edge is listed on the line below the Offset Distance field. Change this value to change the position of the Section Cut.
Include Beam beneath Wall (if any) Set this option to consider the forces in beams crossed by any section cut.
Note: This option is only present for section cuts oriented vertically.
Include Columns at wall ends (if any) Set this option to consider the forces in columns crossed by any section cut.
Note: This option is only present for section cuts oriented horizontally.

Clicking OK will keep these changes. Clicking Cancel discards the changes.