The general properties for Star Seismic® buckling restrained braces can be defined in this dialog.

Selecting Criteria > Buckling Restrained > Star Seismic opens the Star Seismic Criteria dialog.

These values are used for all Star Seismic buckling restrained braces.

SettingDescription
Cd Deflection amplification factor
Fy max / Fy min Yield strength for major and minor axis bending
Minimum Clearance the Minimum Clearance refers to the distance between the column and beam flanges and the end of the brace.
Stiffness Modifier This is axial stiffness modifier. Select to either Use Calculated (by the program) or Use a specific value you type.