The following sections of AS3600-2001 are considered when checking a section for serviceability:
Table 1.
Clause Description
10.7.1 Maximum Longitudinal Reinforcement
11.6.1(a) Minimum Longitudinal Reinforcement
11.6.1(b) Minimum Transverse Reinforcement
11.6.2 Minimum Horizontal Reinforcement for Crack Control
11.6.3

Minimum Longitudinal Bar Spacing

Maximum Longitudinal Bar Spacing

11.6.4 Longitudinal Bar Containment