Serviceability & Detailing Checks
The following sections of AS3600-2001 are considered when checking a section for serviceability:
Clause | Description |
---|---|
10.7.1 | Maximum Longitudinal Reinforcement |
11.6.1(a) | Minimum Longitudinal Reinforcement |
11.6.1(b) | Minimum Transverse Reinforcement |
11.6.2 | Minimum Horizontal Reinforcement for Crack Control |
11.6.3 |
Minimum Longitudinal Bar Spacing Maximum Longitudinal Bar Spacing |
11.6.4 | Longitudinal Bar Containment |