RAM Structural System Help

§2213.5 Column Requirements

Where standard provision load combinations are referred to (such as in exception 2 of Section 2213.5.1), RAM Frame will use the current load combinations from the standard provision mode. The engineer is responsible for ensuring that an appropriate set of loads and combinations are defined in the standard provision mode prior to switching to special seismic mode and performing a code check. Load Combinations 1.0DL + 0.7LL ± ΩoE and 0.85DL ± ΩoE are generated within this mode.