General Analysis Criteria
Before performing the analysis you should always establish your criteria using the Criteria menu. To set the general analysis criteria:
- Set Rigid End Zones to Include Effects and Type 50 for Reduction %. This means that the beams in the rigid frames will be shorted in the analysis to the face of the column.
- Set Member Force Output to At Face of Joint (when using rigid end zones you have no choice).
- Set P-Delta to Yes and Type 1 for Scale Factor. This means that second-order, P-Delta effects will be calculated for all load cases utilizing the building mass Dead Load as the P in the P-delta calculations. If you wanted to also consider part of the Live Loads in the P-Delta calculations, then you can increase the value somewhat.
- Check the Use Reduced Stiffness for Steel Members checkbox, and click on the τb = 1 radio button.
- For the Wall Mesh set the Max. Distance Allowed between Nodes to 8 (2.5). This means that the program will mesh the walls in such a way that no single element is more than 8’ on a side (though they may be smaller due to geometric constraints). More Mesh options are available by clicking the [Advanced] button.
- Check the Store Wall Stresses checkbox for use in the Concrete Shear wall module.
- Click [OK].