Period Determination (Section 12.8-2)

In the current implementation, the fundamental period of the structure, T, can be either calculated from an Eigenvalue analysis or it can be a user input. Alternatively, it is also permitted to use T = Tα, where Tα is approximate fundamental period defined per Section 12.8.2.1.

The following upper limit is enforced on the fundamental period of the structure:

T ≤ CuTα

The term Cu is given in Table 12.8.1.

It should be noted that the fundamental period, T, is calculated separately for each loading direction. In addition, the limit imposted on T according to the above equation is removed if analysis is carried out for story drift calculations.

Design Spectral Response Acceleration Parameter at 1 s, SD1 Coefficient Cu
≥0.4 1.4
0.3 1.4
0.2 1.5
0.15 1.6
≤0.1 1.7