RAM Structural System Help

Data Checking a Model

The Data Check checks the validity and completeness of the database. It has been designed to detect errors in the model that the Analysis or Design module may by unable to detect or that may cause the module to abruptly terminate. This includes incomplete slab edges, missing supports, missing sizes on lateral frame members, etc.

It is important that a Data Check be run on each model before attempting to run any of the Analysis or Design modules. It is up to the user to run the Data Check in the RAM Modeler to verify that the model has no errors.

Icon Description
The Data Check is run by selecting Integrity – DataCheck from the RAM Modeler menu. The type of Data Check to be performed is selected from the Data Check Options dialog box. A “Gravity” Data Check verifies that all data needed to run RAM Steel Beam Design or RAM Steel Column Design is included. A “Frame” Data Check checks verifies that all data needed to run RAM Frame is included. An “Integrated” Data Check verifies that the model can be run in any of the Design modules and should be performed for models that will be run in the RAM Concrete Design modules.

The Data Check only checks floors that are defined in the Story Data.

Items may be listed as either Errors or Warnings. Errors must be corrected before proceeding to the design modules; they may result in either incorrect results or abnormal program termination. Warnings are given for items that may be a problem for certain condition, which are listed with the Warning. Warnings do not need to be corrected unless not doing so will result in undesirable results.

If errors or warnings are found, a message is displayed stating the number of errors and warnings in the model. Clicking OK will display a report listing the errors and warnings, including a "User Action" to fix the error. The report can be printed by selecting Print from the menu or by clicking on the Print Screen toolbar button.