RAM Structural System Help

Error Messages

The following error messages may appear during the design process.

SettingDescription
KLR > 200 or LR > 300 Displayed when the slenderness of a section in compression exceeds the code specified limit of 200, or when the slenderness of a section in tension exceeds the code specified limit of 300 (and the user has selected to consider this check in the Criteria-Axial Slenderness Limits).
fa > Fex or fa > Fey Displayed when the axial force on the section exceeds the elastic buckling capacity of the section. This has implications in the calculation of interaction values.
T-O in Bend Some tension-only members (flat bars, rods etc) do not have bending capacities calculated. This error is issued if one of these member types is subject to a bending force following an analysis.
T-O in Comp Some tension-only members (flat bars, rods etc) do not have compression capacities calculated. This error is issued if one of these member types is subject to a compression force following an analysis. This should only occur if the user assigns a tension-only shape to a member that is then not designated to be tension-only.
A-O in Bend Some members capable of withstanding both tension and compression forces only do not have bending capacities calculated. This error is issued if one of these member types is subject to a bending force following an analysis.