RAM Structural System Help

Member Numbers

Icon Description
Member numbers are initially assigned automatically by the RAM Modeler as members are created, in the order they are created. As new members are added, the next higher available number is assigned. If a member is deleted, that member number is no longer used. This numbering scheme may make it difficult to locate members by number. The Options - Renumber Members command causes all members to be renumbered in consecutive order based on member coordinates, beginning in the lower left corner and working up and then to the right. Note that invoking the Renumber Members command will clear the Undo stack.

If subsequent additions or deletions are made to the model, the member numbering is not automatically updated. New members are assigned the next higher available number regardless of their location, old members retain their numbers, and deleted member numbers are no longer used. If desired, the Options - Renumber Members command can be invoked at any time; otherwise the old numbering assignments will always be retained.

Each layout type has its own set of numbers. For example, there is a column number 1 on every level.

Each element type has its own set of numbers. For example, there is a column number 1 and a beam number 1 on the same level.

Member numbers can be viewed by invoking the appropriate Show Numbers command from the Options menu or by clicking the desired Show Numbers button on the toolbar.

Member numbers are used throughout the RAM Structural System to identify members, especially the output reports.