C-Beam Design Summary
This output provides a listing of every C-Beam™ design in the structure. For each beam, there are two sections of output: Design and Detailing. Castellated and Cellular beams are listed separately.
An asterisk "*" after the beam size indicates that the beam is over‑stressed. This can occur with user-selected sizes. A "#" after the beam size indicates that the beam is over‑deflected. A "u" after the size indicates that the user has assigned the size, hole configuration, and/or studs shown.
The Detailing section lists the following information:
- The beam ID number
- The Root Beam size from which the C-Beam is to be manufactured. The root beam for the top half and the bottom half are both listed.
- The C-Beam size
- The range of acceptable e dimensions, emin and emax, for Castellated beams, and the range of acceptable S dimensions, Smin and Smax, for Cellular beams.
- The dt dimension for Castellated beams, and the Do dimension for Cellular beams
- The angle of the castellation, phi, for Castellated beams. The angle for the top half and the bottom half are both listed.