RAM Structural System Help

Error Messages

These error messages related to Cross Section classification may appear during the design process.

AISC 360

None

ASD or LRFD

"Section is Slender": If a part of the cross section exceeds the slender section limits for flange or web.

CAN/CSA S16

"Class 4": If a section contains a slender element it will be indicated as a class 4 section and no additional design checks will be performed.

“Slender Web”: If a section subject to shear has a web whose depth to thickness ratio exceeds the limit of 502√(kv/Fy) then no further design checks will be performed.

BS 5950

"Class 4": If a section contains a slender element it will be indicated as a class 4 section and no additional design checks will be performed.

Eurocode

"Class 4": If a section contains a slender element it will be indicated as a class 4 section and no additional design checks will be performed.

IS 800-07

"Slender": If a part of the cross section exceeds the slender section limits for flange or web.