Beam and Joist Reaction Summary
This output provides a listing of the reactions of every gravity beam and joist in the structure. This can be very useful in designing connections. The output includes:
- The beam ID number
- The beam or joist size
- The coordinates of the supports
- The dead load reaction
- The positive reduced live load reaction
- The negative reduced live load reaction
- The total positive reaction
- The total negative reaction
All reactions are unfactored reactions, except TOTAL, which are either factored or unfactored, as specified by the user and indicated on the Report.