The following clauses are implemented for column design:
Clause Description
9.5.1 (1) Minimum longitudinal bar diameter
9.5.1 (2) Minimum amount of longitudinal reinforcement
9.5.1 (3) Maximum amount of longitudinal reinforcement
9.5.2 (1) Minimum transverse bar diameter
9.5.2 (3) Maximum spacing of transverse reinforcement
9.5.2 (6) Longitudinal bars restrained by transverse reinforcement