RAM Structural System Help

Longitudinal Reinforcement

This section identifies the controlling load combination and design point the data point with the largest Ld/Cap ratio. Refer to section 0 for a discussion of how Ld/Cap and the angle are calculated.

SettingDescription
P n, MnMajor, MnMinor The axial capacity and corresponding biaxial moments are reported at the same angle as the applied controlling load.
Kl/r, Slender, lu/r limit The slenderness parameters are calculated based on the column properties and unbraced length. Refer to Section 4.3 for information on how these values are calculated.