Longitudinal Reinforcement
This section identifies the controlling load combination and design point the data point with the largest Ld/Cap ratio. Refer to section 0 for a discussion of how Ld/Cap and the angle are calculated.
Setting | Description |
---|---|
P n, MnMajor, MnMinor | The axial capacity and corresponding biaxial moments are reported at the same angle as the applied controlling load. |