RAM Structural System Help

IS 800-07 Design

SettingDescription
P or N This is the total design axial load for the controlling load case. It may be less than the total load due to the skipping of Live Loads associated with the controlling load case.
Mz This is the total design moment about the strong axis for the controlling load case.
My This is the total design moment about the weak axis for the controlling load case.
fc This is the total design axial stress for the controlling load case. It may be less than the total stress due to the skipping of Live Loads associated with the controlling load case.
fbcz This is the total design bending stress about the strong axis for the controlling load case.
fbcy This is the total design bending stress about the weak axis for the controlling load case.
Fy This is the design yield strength for the section.