Sections 11.3.9.2 and 11.3.9.3 Longitudinal Reinforcement Due to Shear

The shear component (Vf – 0.5Vs) cotθ is calculated and added to the cross section forces.

A strain compatibility strength design is then performed in accordance with 10.1.2