RAM Structural System Help

Edit Piles

Piles are defined in the Edit Piles dialog and are assigned to pile caps using the Assign Pile Geometry command.

Pile definitions are given a label and effective diameter. For rectangular or other shaped piles the effective pile diameter will need to be calculated. In addition, the engineer should specify the compression capacity, tension capacity, and shear capacity for the piles. Tension and shear values can be set to zero. Piles are assumed to have no flexural capacity. Piles that have been assigned to pile caps cannot be deleted.

Edit Pile Configurations

Pile configurations are defined in the Edit Pile Configurations dialog and are assigned to pile caps using the Assign Pile Geometry command.

Rectangular pile configurations can be defined using the Edit Pile Configurations command. Note that 2, 3, 5, 5 square, 7, and 8-pile groups are all predefined and available to assign using the Assign Pile Geometry command.