RAM Structural System Help

Wall Group Forces

The Wall Group Forces report lists the integrated wall force results of the frame analysis for user-defined wall groups. It also includes the geometrical information on the wall group, the analysis criteria and a list of load cases analyzed.

This report can be printed for one wall group at a time (Single), for all wall groups in a fenced area (Fence), all wall groups of a specified wall group number (Wall Group), all wall groups currently visible on the screen (Current View) or for all wall groups in the model (All). A report for all wall groups in a model can be quite lengthy.

A similar report is available in the Analysis-Load Combinations Mode.

Member Information

Member information is listed including: the member number, the frame number to which it is assigned, the level on which it is located, its end coordinates, material properties, and member size.

Input Parameters

Analysis criteria as set using the Criteria - General and the Criteria - Ground Level commands are listed here along with the fixed end conditions and calculated joint face distance of the member.