CLT restraint Sets the member with continuous lateral-torsional restraint. This flag affects only the design calculations and when it is used the lateral torsional buckling (LTB) is not considered in the design.
CFT Restraint This options indicates whether the member has continuous torsional and flexural-torsional buckling restraint. If so, the limit state of flexural-torsional and torsional buckling will be ignored in the compression design.
Consider Eccentricity Enabling this option the single angle member slenderness will be calculated according to the section 6.5.4. If the option is unchecked, the design of the single angle will be according to section 5.3.
Conn. TSL This option is only for single angle compression members and defines that the member is connected through the shorter leg.
a (Stiffeners) It is the clear distance between member stiffeners. It is used for the shear check.