Cnx type (connection type)
It is a variable that describes the type of connection that it is being used with the struts. See Table 25.
The following values are possible:
Single angle connected by one leg to a gusset, or directly to another member, at each end:
- Type 1: by a single bolt in the long leg (4.7.10.2c).
- Type 2: by a single bolt in the short leg (4.7.10.2c).
- Type 3: by two bolts in line along the long leg of the angle, one in a standard clearance hole and one in a kidney-shaped slot (4.7.10.2b).
- Type 4: by two bolts in line along the short leg of the angle, one in a standard clearance hole and one in a kidney-shaped slot (4.7.10.2b).
- Type 5: by two or more bolts in line along the long leg of the angle or by equivalent welded connection (4.7.10.2a).
- Type 6: by two or more bolts in line along the long leg of the angle or by equivalent welded connection (4.7.10.2a).
Double angles interconnected back-to-back or battened, connected by one leg of each angle to a gusset, or directly to another member:
- Type 1: to both sides of a gusset or member by a single bolt through each angle (4.7.10.3e).
- Type 2: to both sides of a gusset or member by two bolts in line along each angle (4.7.10.3d).
- Type 3: to both sides of a gusset or member by two or more bolts in standard clearance holes (4.7.10.3c).
- Type 4: to one side of a gusset or member by one bolt in each angle (4.7.10.3b).
- Type 5: to one side of a gusset or member by two or more bolts in line along each angle or by equivalent weld (4.7.10.3a).
Single channels connected only by its web to a gusset, or directly to another member, at each end:
- Type 1: by two or more bolts arranged symmetrically in a single row across the web, or by an equivalent welded connection (4.7.10.4b).
- Type 2: by two or more rows of bolts arranged symmetrically across the web, or by an equivalent welded connection (4.7.10.4a).