RAM Concept Help

Point load properties

The following is a list of RAM Concept point load properties:

SettingDescription
Name User-defined label used to identify the point load in output.
Elevation above slab surface Vertical distance between the point load and the slab surface.
Fx Point force in the direction of global x-axis (horizontal force).
Fy Point force in the direction of global y-axis (horizontal force).
Fz Point force in the direction of global z-axis (vertical force).
Mx Point moment about the global x-axis.
My Point moment about the global y-axis.
Notes:
  • Although point loads need not be located at a finite element node, you should consider locating very large loads at nodes. Point loads must be located on finite elements; RAM Concept issues a warning if you violate this rule.
  • Sign convention is defined in Criteria > Signs. See Choosing Sign Convention .
  • Horizontal forces (Fx, Fy) cause applied moments unless the Elevation above slab surface is set to apply the load at the slab centroid.