Flexural Section Parameters
The parameters in this tab control the design of flexural reinforcement for the transfer of unbalanced moment to the column (see ACI 318-19 8.4.2.2.2) or minimum reinforcement for punching shear requirements (see ACI 318-19 8.6.1.2).
Setting | Description |
---|---|
Top Bar | The label used to identify the top face reinforcing bar used for flexural reinforcement at the column-slab connection. |
Bottom Bar | The label used to identify the bottom face reinforcing bar used for flexural reinforcement at the column-slab connection. |
Top Cover | Clear cover to the top longitudinal bars at the column-slab connection. |
Bottom Cover | Clear cover to the bottom longitudinal bars at the column-slab connection. |
Use Intersecting Span Segment Properties | When selected the bar and cover assignments defined with span segments intersecting the flexural section are used in the design instead of the properties listed above. |