RAM Concept Help

Chapter 8 (Two-way slab systems)

Section 8.4.2.3 for the design of flexural reinforcement to resist unbalanced moment transfer at column-slab connections is implemented. This design check is only completed when the Design Flexural Sections option is selected in the Punching Shear Check Property dialog.