RAM Concept Help

Service

  • Tendons are considered as an external load (and the balance loading is assumed to be included in the load factors).
  • The reinforcement type (as defined in the design section or design strip segment) is considered (PT or RC).
  • The stress levels in the structure are determined by the moment envelope for the rule set (reinforcement may be required on both faces).
  • The design strip segment or design section property "Environment" is used to determine the class of post-tensioned members as follows:
    • Protected: Class C
    • Normal: Class T
    • Corrosive: Class U
    • Very Corrosive: Class U
  • Code Rules are applied as shown in the following table.
Table 1. Service rule mapping
Design System RC PT Class U PT Class T PT Class C
Beam 10.6.4 18.3.3, 18.4.2b 18.3.3, 18.4.2b 10.6.4, 18.4.4
One-Way Slab 10.6.4 18.3.3, 18.4.2b 18.3.3, 18.4.2b 10.6.4, 18.4.4
Two-Way Slab (none) 18.3.3, 18.4.2b, 18.9.3.2 (not applicable) (not applicable)