RAM Concept Help

Concrete Mix

SettingDescription
Mix Name The label used to identify a concrete mix. The mix name is not necessarily the concrete strength. Each column, wall, slab and beam has a concrete mix property.
Density The concrete mass density used to calculate various stiffness properties for Concrete.
Density for Loads The concrete mass density used to calculate self weight.
f’ci The characteristic cylinder strength of the concrete mix at the time of applying prestress (also known as initial strength).
f’c The characteristic cylinder strength of the concrete mix.
Note: f’ci and f’c are used for all codes except BS8110.
fcui The characteristic cube strength of the concrete mix at the time of applying prestress (also known as initial strength).
fcu The characteristic cube strength of the concrete mix.
Note: fcui and fcu are only used for BS8110 and IS456.
Poisson’s Ratio The negative of the ratio of lateral strains to axial strains for an axially loaded material. This is usually 0.2 for concrete.
Coefficient of Thermal Expansion The concrete coefficient of thermal expansion used to calculate temperature strains.
Ec Calc The method used to calculate Young’s Modulus (for both initial characteristic strength and characteristic strength). This can be according to the active code rules or a specified value.
User Eci The user-defined Young’s Modulus used for initial cross section analysis.
User Ec The user-defined Young’s Modulus used for global analysis, service cross section analysis and strength design.