RAM Concept Help

Add drop caps

Enter the dimensions for a drop cap at Supports 2 and 4 in the Drop Caps table (top table) on the Drop Cap and Drop Panels page.

Set the drop cap data as follows

  1. For Support 2 in the Drop Caps table set the following values:
    1. Set the thickness to 20 inches [500 mm].
    2. Set the left width to 22.5 inches [600 mm].
    3. Set the right width to 22.5 inches [600 mm].
    4. Set the before length to 22.5 inches [600 mm].
    5. Set the after length to 22.5 inches [600 mm].
  2. For Support 4 in the Drop Caps table set the following values:
    1. Set the thickness to 20 inches [500 mm].
    2. Set the left width to 33 inches [900 mm].
    3. Set the right width to 12 inches [300 mm].
    4. Set the before length to 33 inches [900 mm].
    5. Set the after length to 0 inches [0 mm].
  3. Click Next to proceed to the Loads page.