Load properties
Area and line loads can be input for two different loadings on each span.
Setting | Description |
---|---|
Dead Area Load | The area load over the entire span. |
Dead Line Load | The line load from the first support center to the second support center for each span. |
Live Area Load | The live load over the entire span. |
Live Line Load | The live load from the first support center to the second support center for each span. |
Loadings to use | The Dead and Live are just names. You can specify the loads as belonging to any of the Standard loadings in the RAM Concept file. |
"Dead" | This can be any one of the standard loadings in the RAM Concept file. |
"Live" | This can be any one of the standard loadings in the RAM Concept file (except for that used for "Dead"). |