RAM Concept Help

Section 10.5.2 Redistribution of Moments - Ductility Check (Non prestressed)

RAM Concept does not currently redistribute moments, but applies equation 10-5 as a limit to the neutral axis depth, thereby ensuring ductility.

Although the current standard does not state an upper limit for the axial compression for ductility checks, a limit of 0.1Agfc’ is applied.