Summary of load combination types
The effects of using different load combination types and analysis types are summarized in the following table.
ACI 318-05 Elevated floor file with lateral loadings added
To simplify the example, four loadings have been deleted from the standard file.
Loading table for ACI 318-05 Elevated Floor - six wind loadings have been added (and one stressing dead and three live loadings have been deleted)
After adding and deleting some loadings, the load combinations have been rebuilt. See "Rebuilding load combinations".
The Rebuild operation adds the load combination "Factored Wind LC: 1.2D + f1L+ 0.5Lr + 1.6W", as shown in the following figure.
RAM Concept now expands this load combination and calculates the following load combinations:
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 North Wind + 1.6 North Wind (transfer)
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 North Wind - 1.6 North Wind (transfer)
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 East Wind
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 East Wind
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 Trade Wind + 1.6 Sirocco Wind + 1.6 Zephyr Wind
- 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 Trade Wind - 1.6 Sirocco Wind - 1.6 Zephyr Wind