Summary of load combination types

The effects of using different load combination types and analysis types are summarized in the following table.

Table 1. Load Combination Summary
 

Linear

Zero-tension
Single
  • Standard and Alternate load factors for every loading
  • No zero-tension iterations
  • Considers pattern loading
  • Standard load factor for every loading
  • Zero-tension iterations as necessary
  • Ignores pattern loading
  • Ignores "Don’t Reduce Integrated M and V Due to Sign Change" option
Group
  • Standard and Alternate load factors for every non-lateral loading
  • Standard and Alternate load factors for the selected lateral loading type
  • No zero-tension iterations
  • Considers pattern loading
  • No results for point springs, line springs, point supports, line supports, walls.
  • No "Standard" results for any quantity
  • See the second figure in this chapter for more information.
  • Standard load factor for every non-lateral loading
  • Standard load factor for the selected lateral loading type
  • Zero-tension iterations as necessary
  • Ignores pattern loading
  • No results for point springs, line springs, point supports, line supports, walls.
  • No "Standard" results for any quantity
  • Ignores "Don’t Reduce Integrated M and V Due to Sign Change" option
  • See the second figure in this chapter for more information.

ACI 318-05 Elevated floor file with lateral loadings added

To simplify the example, four loadings have been deleted from the standard file.

Loading table for ACI 318-05 Elevated Floor - six wind loadings have been added (and one stressing dead and three live loadings have been deleted)

After adding and deleting some loadings, the load combinations have been rebuilt. See "Rebuilding load combinations".

The Rebuild operation adds the load combination "Factored Wind LC: 1.2D + f1L+ 0.5Lr + 1.6W", as shown in the following figure.

Rebuilt load combination: Factored Wind LC: 1.2D + f1L+ 0.5Lr + 1.6W

RAM Concept now expands this load combination and calculates the following load combinations:

  1. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 North Wind + 1.6 North Wind (transfer)
  2. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 North Wind - 1.6 North Wind (transfer)
  3. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 East Wind
  4. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 East Wind
  5. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) + 1.6 Trade Wind + 1.6 Sirocco Wind + 1.6 Zephyr Wind
  6. 1.2 Self-dead + 1.0 Hyperstatic + 1.2 Other dead + 0.5 Live (reducible) - 1.6 Trade Wind - 1.6 Sirocco Wind - 1.6 Zephyr Wind