RAM Concept Help

Pushing Support Members to Analytical iTwin

When pushing support members to Analytical iTwin, pairs of matching support members at the same location are merged to create a single Analytical iTwin support member. Two support members are merged only if all of their properties match (e.g., concrete mix, thickness, etc.), and either they were transferred from the same Analytical iTwin support member, or they are both new in RAM Concept . If a pair of support members at a location cannot be merged, then two Analytical iTwin support members are transferred.

The support member pushed by RAM Concept extends only to the ends of the heights modeled in RAM Concept , relative to the center of the slab or beam the support member passes through. Dealing with this geometry approximation requires some care when updating RAM Concept or the iTwin repository. When updating RAM Concept from Analytical iTwin, the RAM Concept model may have shortened support members. In general, the Analytical iTwin geometry can be accepted to capture changes made to the repository, and RAM Concept will just create a new approximation. There are times when you should reject changes to the RAM Concept support member geometry. For example, when the RAM Concept support member geometry has been adjusted to compensate for a problem in the RAM Concept approximation. In those cases, the Reject setting in the iTwin Analytical Synchronizer update dialog will prevent the RAM Concept geometry from changing.

It is usually not desirable to update the iTwin repository with the approximate RAM Concept support member geometry. For this reason, updating the iTwin repository support member is disabled by default. See Section 16.5.9 for information on enabling updates to support members. If updating support members is enabled, you can decide which properties should be changed. The support member geometry—defined by the Location or Boundary properties—can be updated for simple one or two story support members. Changes to concrete mixes, dimensions or column orientation can also be updated.