RAM Concept Help

Analytical iTwin Load Cases and Loads

Analytical iTwin Load Case objects and their Load Cause property are analogous to RAM Concept Loadings and their Loading Type property. The following table gives the RAM Concept Loading Type pulled from Analytical iTwin for each Analytical iTwin Dead Load Cause.

Table 1. Concept Dead Loading Types Pulled from Analytical iTwin

Analytical iTwin Load Cause

RAM Concept Loading Type

DeadConstruction

Stressing Dead
DeadStructure

Other Dead

DeadSuperimposed

Other Dead

DeadUnspecified Other Dead

The following table gives the RAM Concept Loading Type pulled from Analytical iTwin for each Analytical iTwin Floor Load Cause.

Table 2. Concept Floor Loading Types Pulled from Analytical iTwin

Analytical iTwin Load Cause

RAM Concept Loading Type

FloorAssembly

Live Unreducible

FloorOffice

Live Reducible
FloorResidential Live Reducible

FloorRetail

Live Reducible

FloorStorage

Live Storage

FloorUnspecified Live Reducible
ParkingHeavy Live Parking
ParkingLight Live Parking
ParkingUnspecified Live Parking

The following table gives the RAM Concept Loading Type pulled from Analytical iTwin for each Analytical iTwin Other Load Case.

Table 3. Concept Roof Loading Types Pulled from Analytical iTwin

Analytical iTwin Load Cause

RAM Concept Loading Type

RoofAccess

Live Roof

RoofRain

Live Roof

RoofSnowDrift

Snow

RoofSnowUniform

Snow

RoofSnowUnspecified

Snow

RoofUnspecified

Live Roof

The following table gives the RAM Concept Loading Type pulled from Analytical iTwin for each Analytical iTwin Other Load Case.

Table 4. Concept Lateral Loading Types Pulled from Analytical iTwin
Analytical iTwin Load Cause RAM Concept Loading Type

SeismicService

Seismic Service
SeismicUltimate Seismic Ultimate
SeismicUnspecified Seismic Ultimate

WindService

Wind Service
WindUltimate Wind Ultimate
WindUnspecified Wind Service

The following table gives the RAM Concept Loading Type pulled from Analytical iTwin for each Analytical iTwin Other Load Case.

Table 5. Concept Other Loading Types Pulled from Analytical iTwin

Analytical iTwin Load Cause

RAM Concept Loading Type
EarthPressureService Other

EarthPressureUltimate

Other
EarthPressureUnspecified Other

FloorConstruction

Other
FluidContained Other
FluidUncontained Other

FluidUnspecified

Other

GroundWaterPressure

Other
Hydrodynamic Other

Hydrostatic

Other
Ice Other
Other Other
PostTensioning Balance

Settlement

Other
Shrinkage Other
Thermal Other

The following table defines the Analytical iTwin Load Case pushed into Analytical iTwin for each RAM Concept Loading Type.

Table 6. RAM Concept Load Types Pushed into Analytical iTwin

RAM Concept Loading Type

Analytical iTwin Load Cause
Balance

PostTensioning

Stressing Dead

DeadConstruction

Other Dead

DeadSuperimposed

Live Reducible

FloorUnspecified
Live Unreducible FloorAssembly
Live Storage FloorStorage

Live Parking

ParkingUnspecified
Live Roof

RoofAccess

Snow RoofSnowUnspecified
Other Other
Wind Service WindService
Wind Ultimate

WindUltimate

Seismic Service

SeismicService

Seismic Ultimate

SeismicUltimate

The Balance loading is not pushed to Analytical iTwin by default. It is not always useful to other programs, and it may significantly increase the size of the iTwin repository. See the Options section below for information on enabling Balance loading transfer.