RAM Concept Help

Chapter 8 (Two-way slab systems)

Section 8.4.2.2 for the design of flexural reinforcement to resist unbalanced moment transfer at column-slab connections is implemented.

Section 8.6.1.2 for the design of minimum flexural reinforcement at highly stressed punching shear sections is implemented.

The design checks listed above are only completed when the Design Flexural Sections option is selected in the Punching Shear Check Property dialog.