RAM Concept Help

Types of active rules

The available ACI 318-02 active rules are:

SettingDescription
Code Minimum Design

Rules for minimum reinforcement (shrinkage, detailing, etc.) based upon geometry rather than stress or moment level. Does not include shear reinforcement.

User Minimum Design Reinforcement based on user defined reinforcement ratio. See the design strip property description in chapter 22.
Initial Service Design Checks of PT floor stresses just after application of prestress (when dead load is minimal).
Service Design Checks of PT floor stresses due to service loads.

Rules for reinforcement bar based upon bar stress levels.

Sustained Service Design Checks of PT floor compression stresses due to sustained loads.
Strength Design Rules to ensure section has sufficient strength in bending and shear for factored (or ultimate) moments, and minimum shear reinforcement.
Ductility Design Rules intended to produce ductile behavior.
Soil Bearing This is used in mat foundation (raft) files to facilitate the enveloping of soil bearing pressure. It does not use any active rules.