RAM Concept Help

Characteristic Service

  • Tendons are considered as an external load (and the balance loading is assumed to be included in the load factors).
  • The reinforcement type (as defined in the design section or design strip segment) is considered (PT or RC).
  • The stress levels in the structure are determined by the moment envelope for the rule set (reinforcement may be required on both faces).
  • The design strip segment or design section property "Environment" is used to determine the exposure category of members as follows:
    • Protected: X0, XC1
    • Normal: XC2, XC3, XC4
    • Corrosive, Very Corrosive: XD1, XD2, XS1, XS2, XS3
  • Code Rules are applied as shown in the following table:
Table 1. Characteristic service rule mapping
Design System RC Bonded PT Unbonded PT

UK National Annex

     
Beam

7.2 (2)

7.2 (5)

7.2 (2)

7.2 (5)1

7.2(5)1

One-Way Slab

7.2 (2)

7.2 (5)

7.2 (2)

7.2 (5)1

7.2(5)1

Two-Way Slab

7.2 (2)

7.2 (5)

7.2 (2)

7.2 (5)1

TR-43 5.8.12 (Table 4)

TR-43 5.8.72

7.2(5)1

TR-43 5.8.12 (Table 4)

TR-43 5.8.72

Generic National Annex      

All systems

7.2 (2)

7.2 (5)

7.2 (2)

7.2 (5)

7.2 (2)

7.2 (5)

Note: 1 - for PT members 7.2(5) is only performed where "crack width" design is requested.
Note: 2 - TR-43 5.8.1/5.8.7 hypothetical stress limit design is only performed where "stress" design is requested.