Service
- Tendons are considered as an external load (and the balance loading is assumed to be included in the load factors).
- The reinforcement type (as defined in the design section or design strip segment) is considered (PT or RC).
- The stress levels in the structure are determined by the moment envelope for the rule set (reinforcement may be required on both faces).
- The design strip segment or design section property "Environment" is used to determine the exposure category of members as follows:
- Code Rules are applied as shown in the following table.
Design System | RC | Partial PT | Full PT 18.3.2(c) | Full PT 18.3.2(d) |
---|---|---|---|---|
Beam | 10.6.1 | 18.8.1, 18.8.3 | 18.8.1, 18.3.2(c) | 18.8.1, 18.3.2(d) |
One-Way Slab | 10.6.1 | 18.8.1, 18.8.3 | 18.8.1, 18.3.2(c) | 18.8.1, 18.3.2(d) |
Two-Way Slab |
(none) |
(not applicable) |
18.8.1, 18.3.2(c) | 18.8.1, 18.3.2(d) |