Drawing the loads
RAM Concept calculates the concrete self-weight automatically. There is no limit to the number of loadings than can be specified but this example defines only Live Loading.
- Choose Layers > Loadings > Live (Reducible) Loading > All Loads Plan.
- Double click the Area Load tool ().
- In the Default Area Load Properties dialog box: This tool will now draw area loads of 50 psf [2.5 kN/ m2].
- Define an area load over the entire slab by clicking four corners of a quadrilateral and then typing "c". This shape need not match the slab’s exact dimensions, but should cover the slab.