Section 26.5.2.1

Reinforcement is provided in accordance with 0.12 percent requirement. This assumes that high strength deformed bars have been provided.

Post-tensioning is ignored.

This provision is applied to slabs only.

User defined reinforcement that is at an angle to the cross section will only have the component perpendicular to the cross section considered.