Check for punching shear
-
Choose Layers > Design Strip > Punching Checks Plan.
-
Double click the Punching Shear Check tool ().
-
In the Default Punching Shear Check Properties dialog box:
-
Change Cover to CGS to 41 mm (cover to centroid of top reinforcement).
-
Click OK.
-
Fence the slab with the Punching Shear Check tool.
-
Select the punch checks at B.8-1 and C-3.
-
Right click on the plan and choose Selection Properties from the popup menu
-
Change the Maximum Search Radius to 2 m.
-
Click OK.
Design Strip: Punching Checks Plan.