RAM Concept Help

Example of Influence Areas

The following figures show RAM Concept 's influence areas and the influence areas commonly used by engineers for a few slab conditions.

Some engineers might (erroneously) suggest that the tributary area of the column in the following figure is 600 square feet, but continuity effects would obviously increase that value. The results show that the tributary area is actually 952 square feet.

Slab layout with dimensions in feet from center of column to centerline of walls. An engineer would typically deem the influence area to be 2400 square feet.

Column and punching check influence areas as calculated by RAM Concept

Design strip segments

Design strip segment influence areas as calculated by RAM Concept

Column and punching check influence areas for an irregular floor.