Service Seismic LC: D + 0.8L + 0.2S + 0.8E
This load combination is intended for checking the serviceability limit state with applied seismic and live loads. It is currently only generated for mat / raft foundations. Only the live load percentages specified in Table 8 of IS 1893 (Part 1): 2002 are applied. 25% of the Live (Unreducible) and Live (Reducible) loads are applied, and 50% of the Live (Storage) loads are applied. No Live (Roof) loads are applied. These percentages are incorporated into the following combinations. The load factors used are:
Balance Loading: 1.0 (std & alt)
Dead Loading: 1.0 (std & alt)
Live (Reducible) Loading: 0.2 (std & alt) [0.25(0.8)]
Live (Reducible) Loading: 0.2 (std & alt) [0.25(0.8)]
Live (Storage) Loading: 0.4 (std & alt) [0.5(0.8)]
Live (Parking) Loading: 0.2 (std & alt) [0.25(0.8)]
Snow Loading: 0.2 (std & alt) [0.25(0.8)]
Service Seismic Loading: 0.8 (std & alt)