RAM Concept Help

Check for punching shear

  1. Choose Layers > Design Strip > Punching Checks Plan.
  2. Double click the Punching Shear Check tool ().
  3. In the Default Punching Shear Check Properties dialog box:
    1. Change Cover to CGS to 3 inches [60 mm] (cover to centroid of top reinforcement).
    2. Click OK.
  4. Fence the slab with the Punching Shear Check tool.

Design Strip: Punching Checks Plan.