RAM Concept Help

Quasi-Permanent Service

  • Tendons are considered as an external load (and the balance loading is assumed to be included in the load factors).
  • The reinforcement type (as defined in the design section or design strip segment) is considered (PT or RC).
  • The stress levels in the structure are determined by the moment envelope for the rule set (reinforcement may be required on both faces).
  • The design strip segment or design section property "Environment "is used to determine the exposure category of members as follows:
    • Protected: X0, XC1
    • Normal: XC2, XC3, XC4
    • Corrosive, Very Corrosive: XD1, XD2, XS1, XS2, XS3
  • Code Rules are applied as shown in the following table:
Table 1. Quasi-Permanent service rule mapping
Design System RC

Bonded PT

Unbonded PT
UK National Annex      
All systems

7.3

7.32 7.31
Generic National Annex      
All systems

7.3

7.32

7.3

Note: 1- for Unbonded PT members, 7.3 is only performed where "crack width" design is requested.
Note: 2- for Bonded PT members, only the decompression design is applied for the appropriate exposure.