RAM Concept Help

What the estimate calculates

The material quantities calculated are:

SettingDescription
Concrete The volume of the concrete floor excluding supports.
Formwork The area of horizontal soffit formwork.
Post-Tensioning The weight of strand based upon tendon plan length. This does not include stressing tails or allowance for drape.
Mild Steel Reinforcing The weight of reinforcement based upon the detailed reinforcement in the Reinforcement layer. This does include bar hooks, but does not include laps. The quantities do not include bars not shown in the Reinforcement layer such as "detailing" or tendon support bars.